1. Fault phenomenon: the indicator light of the three roller gate does not light up
Solution: Check the power supply or fuse
2. Fault phenomenon: there is a crash sound when the three-roller gate is opened
Disposal method: adjust the strength of the damper
3. Fault phenomenon: there is a buzzing sound when the three-roller gate is opened
Disposal method: adjust the four corner screws of the electromagnet to reduce the suction gap of the electromagnet
Fourth, the fault phenomenon: the three-roller gate cannot be opened

Face recognition gate, hospital gate, school gate, construction site gate Disposal method:
1. Check the control panel;
2. Check whether the electromagnet screw is loose or broken;
3. Check the drive board of the three-roller gate. At this time, you can short-circuit the input end of the drive board (1# open gate or 2# open gate input), if the solenoid valve or the green light has a response, it is normal
5. Fault phenomenon: the three-roller gate cannot be moved manually
Disposal method:

1. Check whether the electromagnet of the power drop bar can attract the iron block;
Turnstile gate |Flap turnstile |Outdoor turnstiles|Outdoor turnstile |Turnstile technology | Flap barrier gate |Revolving gate|Flap barrier | Turnstile suppliers
Puerta de torniquete | Torniquete de aleta | Torniquete de exterior | Torniquete de exterior | Tecnología de torniquetes | Puerta de barrera de aleta | Puerta giratoria | Barrera de aleta | Proveedores de torniquetes
2. Whether the electromagnet of the power-down rod can have DC12V power supply;
3. Check whether the electromagnetic installation of the power-off drop bar can reach the spring plate in the turntable. If so, move the whole installation up so that the two do not come into contact.
The need to pay attention to the use of the three-roller gate are as follows:
1. Please swipe your card outside the yellow line. The gate is fully open and there is a direction indicating arrow to indicate that you can enter. During the walking process, please do not stay in the passage or return to pass.
2. During the passage, please do not follow into the passage, and do not squeeze the rod to swipe the card, so as to avoid the phenomenon that the gate cannot be opened by swiping the card.
3. When you see that the gate is fully opened, please don't forget to swipe your card (for the delayed door closing function), it is indeed a request for one card and one person.
4. Maintenance work, clean the dust inside and outside the chassis, add lubricating oil to the mechanical joints, etc. to ensure the normal operation of the equipment.
5. Please do not damage the turnstile (man-made damage is not covered by the warranty).
entrance control system,entrance control,turnstile gate,speed gate,cloud access control,turnstyle,baffle gate, barrier gate,Turnstiles | Full Height | Automatic | Tripod | Wall Mount | Engineering,turnstile
Turnstiles | Full Height | Automatic | Tripod | Wall Mount | Optima Engineering,Cheap Three roller gate,Cheap Shift gate,Cheap Speed gate,Cheap Speed gate,Cheap One word gate,Cheap Turnstile,Cheap Fence gate,Cheap Turnstile,Cheap Baffle door
Three roller gate,sliding gate turnstiles,speed gate turnstile,turnstile manufacturer,optical turnstile,tripod gate,Office|The company|Office Building|park|School|Government|library|Art gallery|Beauty salon |Airport|Bar|Club|Subway|Service|Center|Graduate