With the continuous progress of science and technology, people pay attention to a safe and orderly lifestyle, which is the most important place for people’s safety management and risk control. At present, the community advertising door system has positive significance and application value for standardizing pedestrian traffic order and improving management efficiency and safety. In short, it is estimated that you do not know the specific advantages of the community advertising door system. Today, Elefine Technology will analyze the advantages of community advertising door system.
1. Easy to use. The existing access control management personnel need simple training to work. The maintenance personnel of the community advertising door can find the fault through several simple steps and eliminate it quickly.
With the continuous progress of science and technology, people pay attention to a safe and orderly lifestyle, which is the most important place for people’s safety management and risk control. At present, the community advertising door system has positive significance and application value for standardizing pedestrian traffic order and improving management efficiency and safety. In short, it is estimated that you do not know the specific advantages of the community advertising door system. Today, Elefine Technology will analyze the advantages of community advertising door system.
1. Easy to use. The existing access control management personnel need simple training to work. The maintenance personnel of the community advertising door can find the fault through several simple steps and eliminate it quickly.
2. Rigorous technology. The technical personnel carry out the product development, production, inspection and sales in full accordance with the product development process, and strive to be scientific and rigorous in every link. After millions of tests, the products can reach the hands of customers, and the quality is guaranteed.
3. Highly integrated. The advertising door of the community has a strong comprehensive interface, which can be upgraded and expanded in the later construction. It is safe and durable, low failure rate and high cost.
4. High security. Through high-tech technologies such as infrared sensor, traffic logic judgment, motor torque feedback, current and mechanical structure, the anti pinch protection can be realized for the advertising door of the community.
5. Fast traffic speed. The response speed of the advertising door in the community is fast. Swipe the card and respond quickly in 0.1 seconds. It is forbidden to open the door, with an average of 30-40 people / minute, which is conducive to rapid passage.
With the development of the real estate industry, there is a great demand for community advertising doors. People also have high technical requirements for community advertising doors. As an advanced enterprise in the security industry, Elefine Technology has strengthened the research and development of pedestrian advertising Lane doors, provided intelligent products and services for pedestrian safe travel, paid attention to product quality and contributed to the construction of intelligent security.
Application:
1. Pedestrian access swing door
2. Access swing door of enterprises and institutions
3. Automatic swing door at industrial site
4. All swing doors requiring automatic opening and closing
Machine parameters:
Model No.: Model No.: EF-GGM03
Product name: Advertising door
Material: Aluminum alloy
Color: Black
Application: Outdoor
Usage: Multi-application Crowd Control Stanchion
Type: Straight Barrier
Surface treatment: Galvanized + Powder Coated
Feature: Anti-corrosion
Name: Galvanized Highway Guardrail
Size: Customized Size
Rated voltage: DC12V
Rated current: 6A
Maximum load: 96w
Maximum torque: 80nm
Opening speed: < = 4 seconds
Applicable door width: < = 2000mm
Applicable door weight: < = 150kg
Overall dimension: 1638mm (H) x1475mm (W)
Access control interface: dry contact and wet contact
Electronic lock: electromagnetic lock
Continuous switching times: 1 million times
Working temperature and humidity: – 20 ℃ ~ 50 ℃ < = 85%
IP grade: 43 (dustproof and waterproof)
Basic functions:
1. Working mode: automatic mode and normally open mode;
2. It can be directly connected with radar, infrared, password keyboard, fingerprint recognition, face recognition instrument and other equipment to control the door opening;
3. The starting point of opening the door is set well, and there is no need to reset it after power off;
4. The door opening angle does not need to be learned and can be set directly through the keyboard;
5. The door is opened and closed in place for buffering, and the buffering angle is adjustable;
6. Stop in case of resistance during door opening and closing, and the sensitivity in case of resistance is adjustable;
7. In the non open state: after the door is opened in place, it will close automatically after a delay of some time, and the delay time is adjustable; In normally open state: it will not close automatically after the door is opened in place;
8. Close the door in place and push it after unlocking to open the door automatically;
9. Close the door in place and lock it automatically;
10. The wireless remote controller adopts learning code, which can be used after learning;
11. The wireless remote controller can be directly used to control opening, closing, stopping and unlocking;
12. It can be installed on the lintel or door body without being affected by the left and right installation positions;
13. With green channel interface. As long as there is an effective signal input at the green channel port, the door body will always remain normally open;
14. It can be externally connected with electronic locks to support electronic locks commonly used in the market;
15. Two working modes:
Automatic mode: induction or key press or remote control → unlock → open the door → open the door buffer → open the door in place → open the door for holding time → close the door → close the door buffer → close the door in place → lock;
Normally open mode: sensing or pressing the key or remote control → open the door → open the door buffer → open the door until → keep the door open → sensing or pressing the key or remote control → close the door → close the door buffer → close the door in place → lock;
Parameter Description:
0: when the door is closed in place, the “green channel / infrared protection line” will open the door if there is a signal; When the door is closed, the door will be opened if there is a signal on the “open / close signal line”.
1. When the door is closed in place, the “green channel / infrared protection line” will not open the door if there is a signal; In the process of closing the door, if there is a signal on the “open / close signal line”, open the door;
2. After the door is closed in place, the door will be opened if there is a signal from the “green channel / infrared protection line”; In the process of closing the door, if there is a signal on the “open / close signal line”, continue to close the door and do not respond to this signal;
3. When the door is closed in place, the “green channel / infrared protection line” will not open the door if there is a signal; In the process of closing the door, if there is a signal on the “open / close signal line”, continue to close the door and do not respond to this signal;
11 F11 external lock type 1: electric plug-in lock (power on locking) 2: Spiritual lock (positive unlocking) 3: electromagnetic lock (power on locking 4: electric control lock)
12 F12 “door opening / closing signal line” signal action and “green channel / infrared protection line” signal action
13 f13 delay time before unlocking after unlocking gear 0 (min) – gear 99 (max)
14 F14 delay time before closing door: gear 0 (min) – gear 99 (max)
1. Power input line (black and red): the black line is connected to the negative pole of the power supply, and the red line is connected to the positive pole of the power supply. And the black line is the common end;
2. Electronic lock power control line (yellow): the yellow line is connected to the positive pole of the electronic lock, and the black line (common end) is connected to the negative pole of the electronic lock;
3. Open / close door signal line (green): the green line is a dry contact passive open / close signal input line. Open the door when the signal is valid when the door is closed in place; In the process of closing the door, if a valid signal is input and F12 parameter is equal to 0 or 1, the door will be reopened; In the process of closing the door, if a valid signal is input and F12 parameter is equal to 2 or 3, the door will continue to close without responding to this signal; If the signal is valid when the door is opened in place, the door will be closed. Short circuit this line with the public line (black) for 200ms, and the disconnection signal is valid, which has the same function as K2 key on the setting board and a key on the remote controller;
4. Normally open control line (gray): the gray line is a dry contact passive normally open signal input line. The disconnection signal is valid after 200 milliseconds of short circuit between this line and the common line (black)
Description of each state under operation state:
1 close the door in place “1” close the door to the starting position
2 stop in case of resistance “8” stop in case of resistance at any position
3 open the door in place “12” open the door in place
4 “6” open the door
5 door opening buffer “9” door opening buffer
6 “7” in closing
7 “10” in closing buffer
8 manual stop “15” press the stop key to stop manually
9 set “set” to set the left and right machine, the starting point and direction of door opening
1. Switching between normally open mode and non open mode;
1) Send the normally open command through RS485, normally open, and restore the non open mode until the door is closed in place;
2) After the door is opened in place, press the K3 key on the setting board or press the B key on the remote control to be normally open until the door is closed in place and the non open mode is restored;
3) The green channel interface continues to input valid signal and is normally open until the limited signal of the green channel interface disappears and recovers;
4) Set the parameter automatic holding time of door opening to 0. After the door is opened in place, it will be normally open. If it is controlled, it will remain in the normally open mode after the door is closed;
5) When the door is opened in place in the normally open mode, after closing or breaking the door manually, the door will automatically open in place 2 seconds after the door stops;
6) In the normally open mode, after stopping in case of resistance, the door operator will wait for 7 seconds and then close the door automatically;
2. The difference between blocking stop and manual stop:
1) Manual stop is the state in which the operation is stopped by pressing the stop key. From the stop state to the switch movement state, it can only be realized by pressing the manual door opening key and manual door closing key;
2) The key can be used to realize the time from opening the door and closing the door to stop automatically when the key meets the resistance, and the key can also be used to realize the time from opening the door to closing the door automatically when the key meets the resistance. Resistance sensitivity can be adjusted according to actual needs.
7、 Wireless remote control:
1. The frequency band of the remote controller is 433M, and the remote controller can be used after learning on the motherboard;
2. Remote control learning method:
1) Press the “remote control learning key” on the setting board,
2) After waiting for 1 second, press the a key on the remote control,
3) Wait another second and press the a button on the remote control again,
4) Wait 3 seconds. The learning process is over.
5) You can learn up to 16 remote controls.
3. How to use the remote control:
A when the door is opened in place, press this key to close the door;
When the door is closed in place, press this key to open the door;
When the door is closed and the parameter F12 is equal to 0 or 1, press this key to reopen the door
B when the door is closed in place and locked, press this key to lock;
When the door is closed in place and locked, press this key to unlock;
When the door is opened in place, press this key to enter the normally open mode;
4. Remote control deletion method:
1) Press and hold the “remote control learning key” on the setting board for 10 seconds;
2) Release, the clearing process is completed, and one operation will clear all stored remote controls.
Installation sites:
Common fault handling:
No “didi” sound after power on?
1. Check whether the output voltage of the power supply is normal. If not, replace the power supply;
2. Check whether the power supply is correctly connected to the host. If not, reconnect the power supply.
The opening and closing of the door are not coherent and smooth, and there is shaking phenomenon?
1. Check whether the power load can drive the electronic lock and motor. If not, replace the power supply;
2. Check the thickness of the connecting line between the power output line and the input line of the door opener. If the line is thin, replace the thick line (network cable cannot be used);
3. After power failure, confirm that the door can be pushed smoothly by hand without obvious resistance. If there is obvious resistance, please readjust the installation position of the door opener;
4. When powered on, please increase the resistance sensitivity F9 or reduce the opening speed and closing speed.
After the door is opened in place, the door keeps shaking?
Whether the Green function line (on / off key line) is connected with the shell (or public end ground) for a long time. If the door jitter is inevitable, please disconnect it;
The remote control doesn’t work?
1. Confirm that there is a battery in the remote control and the power is sufficient. If there is a problem, please replace the battery;
2. Keep the remote control away from the door machine and then remote control;
3. Open the cover and learn the remote control again according to the learning operation process of the remote control.
The electronic lock cannot be locked or unlocked smoothly?
1. Confirm that the electronic lock is the same as the system setting lock. If it is different, please adjust the lock type;
2. If the door cannot be locked: the door is not in place, please increase the locking force of the door, reduce the buffer of the door, or increase the closing speed, so that the door can be closed in place smoothly;
3. If the door cannot be unlocked: please increase the delay time of unlocking and give the electronic lock enough time to disengage;
4. Confirm whether the electronic lock is damaged. If there is any fault, please replace the electronic lock with good function.
Can’t the door always be opened to the set angle?
1. Horizontally move and adjust the relative position of the door opener and the door shaft;
2. Please reset the rotation angle of the output shaft.
The door cannot be closed automatically after opening the door
1. Confirm whether it works in normally open mode. If so, please switch to non open mode;
2. Confirm whether there are signals entering the two green channel ports. If so, cancel the signal;
If the door switch is irregular, please reset the starting point and opening direction. If it cannot be solved, please contact the manufacturer.